@@ -157,20 +157,22 @@ func ComputeClusterCosts(client prometheus.Client, provider cloud.Provider, wind
|
|
|
const fmtQueryCPUModePct = `sum(rate(node_cpu_seconds_total[%s]%s)) by (cluster_id, mode) / ignoring(mode)
|
|
|
group_left sum(rate(node_cpu_seconds_total[%s]%s)) by (cluster_id)`
|
|
|
|
|
|
- // TODO niko/clustercost account for cluster_id in the queries below
|
|
|
+ const fmtQueryRAMSystemPct = `sum(sum_over_time(container_memory_usage_bytes{container_name!="",namespace="kube-system"}[%s:1m]%s)) by (cluster_id)
|
|
|
+ / sum(sum_over_time(kube_node_status_capacity_memory_bytes[%s:1m]%s)) by (cluster_id)`
|
|
|
|
|
|
- // TODO niko/clustercost change to cumulative System and divide by cumulative Total
|
|
|
- const fmtQueryRAMSystemPct = `sum(avg_over_time(container_memory_usage_bytes{container_name!="",namespace="kube-system"}[%s]))
|
|
|
- / sum(avg(kube_node_status_capacity_memory_bytes) by (node))`
|
|
|
-
|
|
|
- // TODO niko/clustercost change to cumulative User and divide by cumulative Total
|
|
|
// TODO niko/clustercost should we subtract System from this? i.e. does working set include system?
|
|
|
- const fmtQueryRAMUserPct = `avg_over_time(kubecost_cluster_memory_working_set_bytes[%s])
|
|
|
- / sum(kube_node_status_capacity_memory_bytes)`
|
|
|
+ const fmtQueryRAMUserPct = `sum(sum_over_time(kubecost_cluster_memory_working_set_bytes[%s:1m]%s)) by (cluster_id)
|
|
|
+ / sum(sum_over_time(kube_node_status_capacity_memory_bytes[%s:1m]%s)) by (cluster_id)`
|
|
|
|
|
|
// TODO niko/clustercost PV breakdown queries
|
|
|
|
|
|
- queryTotalLocalStorage := provider.GetLocalStorageQuery(window, offset, false)
|
|
|
+ // TODO niko/clustercost metric "kubelet_volume_stats_used_bytes" was deprecated in 1.12, then seems to have come back in 1.17
|
|
|
+ // const fmtQueryPVStorageUsePct = `(sum(kube_persistentvolumeclaim_info) by (persistentvolumeclaim, storageclass,namespace) + on (persistentvolumeclaim,namespace)
|
|
|
+ // group_right(storageclass) sum(kubelet_volume_stats_used_bytes) by (persistentvolumeclaim,namespace))`
|
|
|
+
|
|
|
+ queryUsedLocalStorage := provider.GetLocalStorageQuery(window, offset, false, true)
|
|
|
+
|
|
|
+ queryTotalLocalStorage := provider.GetLocalStorageQuery(window, offset, false, false)
|
|
|
if queryTotalLocalStorage != "" {
|
|
|
queryTotalLocalStorage = fmt.Sprintf(" + %s", queryTotalLocalStorage)
|
|
|
}
|
|
|
@@ -186,20 +188,21 @@ func ComputeClusterCosts(client prometheus.Client, provider cloud.Provider, wind
|
|
|
queryTotalRAM := fmt.Sprintf(fmtQueryTotalRAM, window, fmtOffset, window, fmtOffset)
|
|
|
queryTotalStorage := fmt.Sprintf(fmtQueryTotalStorage, window, fmtOffset, window, fmtOffset, queryTotalLocalStorage)
|
|
|
queryCPUModePct := fmt.Sprintf(fmtQueryCPUModePct, window, offset, window, offset)
|
|
|
-
|
|
|
- queryRAMSystemPct := fmt.Sprintf(fmtQueryRAMSystemPct, window)
|
|
|
- queryRAMUserPct := fmt.Sprintf(fmtQueryRAMUserPct, window)
|
|
|
-
|
|
|
- numQueries := 8
|
|
|
-
|
|
|
- klog.V(4).Infof("[Debug] queryDataCount: %s", queryDataCount)
|
|
|
- klog.V(4).Infof("[Debug] queryTotalGPU: %s", queryTotalGPU)
|
|
|
- klog.V(4).Infof("[Debug] queryTotalCPU: %s", queryTotalCPU)
|
|
|
- klog.V(4).Infof("[Debug] queryTotalRAM: %s", queryTotalRAM)
|
|
|
- klog.V(4).Infof("[Debug] queryTotalStorage: %s", queryTotalStorage)
|
|
|
- klog.V(4).Infof("[Debug] queryCPUModePct: %s", queryCPUModePct)
|
|
|
- klog.V(4).Infof("[Debug] queryRAMSystemPct: %s", queryRAMSystemPct)
|
|
|
- klog.V(4).Infof("[Debug] queryRAMUserPct: %s", queryRAMUserPct)
|
|
|
+ queryRAMSystemPct := fmt.Sprintf(fmtQueryRAMSystemPct, window, offset, window, offset)
|
|
|
+ queryRAMUserPct := fmt.Sprintf(fmtQueryRAMUserPct, window, offset, window, offset)
|
|
|
+
|
|
|
+ numQueries := 9
|
|
|
+
|
|
|
+ // TODO niko/clustercost V(4)
|
|
|
+ klog.Infof("[Debug] queryDataCount: %s", queryDataCount)
|
|
|
+ klog.Infof("[Debug] queryTotalGPU: %s", queryTotalGPU)
|
|
|
+ klog.Infof("[Debug] queryTotalCPU: %s", queryTotalCPU)
|
|
|
+ klog.Infof("[Debug] queryTotalRAM: %s", queryTotalRAM)
|
|
|
+ klog.Infof("[Debug] queryTotalStorage: %s", queryTotalStorage)
|
|
|
+ klog.Infof("[Debug] queryCPUModePct: %s", queryCPUModePct)
|
|
|
+ klog.Infof("[Debug] queryRAMSystemPct: %s", queryRAMSystemPct)
|
|
|
+ klog.Infof("[Debug] queryRAMUserPct: %s", queryRAMUserPct)
|
|
|
+ klog.Infof("[Debug] queryUsedLocalStorage: %s", queryUsedLocalStorage)
|
|
|
|
|
|
// Submit queries to Prometheus asynchronously
|
|
|
var ec util.ErrorCollector
|
|
|
@@ -231,6 +234,9 @@ func ComputeClusterCosts(client prometheus.Client, provider cloud.Provider, wind
|
|
|
chRAMUserPct := make(chan []*PromQueryResult, 1)
|
|
|
go AsyncPromQuery(queryRAMUserPct, chRAMUserPct, ctx)
|
|
|
|
|
|
+ chUsedLocalStorage := make(chan []*PromQueryResult, 1)
|
|
|
+ go AsyncPromQuery(queryUsedLocalStorage, chUsedLocalStorage, ctx)
|
|
|
+
|
|
|
// After queries complete, retrieve results
|
|
|
wg.Wait()
|
|
|
|
|
|
@@ -255,9 +261,11 @@ func ComputeClusterCosts(client prometheus.Client, provider cloud.Provider, wind
|
|
|
resultsRAMSystemPct := <-chRAMSystemPct
|
|
|
close(chRAMSystemPct)
|
|
|
|
|
|
- // TODO niko/clustercosts
|
|
|
- // resultsRAMUserPct := <-chRAMUserPct
|
|
|
- // close(chRAMUserPct)
|
|
|
+ resultsRAMUserPct := <-chRAMUserPct
|
|
|
+ close(chRAMUserPct)
|
|
|
+
|
|
|
+ resultsUsedLocalStorage := <-chUsedLocalStorage
|
|
|
+ close(chUsedLocalStorage)
|
|
|
|
|
|
dataMins := mins
|
|
|
if len(resultsDataCount) > 0 && len(resultsDataCount[0].Values) > 0 {
|
|
|
@@ -308,7 +316,6 @@ func ComputeClusterCosts(client prometheus.Client, provider cloud.Provider, wind
|
|
|
|
|
|
cpuBreakdownMap := map[string]*ClusterCostsBreakdown{}
|
|
|
for _, result := range resultsCPUModePct {
|
|
|
- // TODO niko/clustercost account for multi-cluster here
|
|
|
clusterID, _ := result.GetString("cluster_id")
|
|
|
if clusterID == "" {
|
|
|
clusterID = defaultClusterID
|
|
|
@@ -334,13 +341,10 @@ func ComputeClusterCosts(client prometheus.Client, provider cloud.Provider, wind
|
|
|
default:
|
|
|
cpuBD.Other += result.Values[0].Value
|
|
|
}
|
|
|
-
|
|
|
- klog.Infof("[Debug] cpuBD: %+v", cpuBD)
|
|
|
}
|
|
|
|
|
|
ramBreakdownMap := map[string]*ClusterCostsBreakdown{}
|
|
|
for _, result := range resultsRAMSystemPct {
|
|
|
- // TODO niko/clustercost account for multi-cluster here
|
|
|
clusterID, _ := result.GetString("cluster_id")
|
|
|
if clusterID == "" {
|
|
|
clusterID = defaultClusterID
|
|
|
@@ -352,7 +356,32 @@ func ComputeClusterCosts(client prometheus.Client, provider cloud.Provider, wind
|
|
|
|
|
|
ramBD.System += result.Values[0].Value
|
|
|
|
|
|
- klog.Infof("[Debug] ramBD: %+v", ramBD)
|
|
|
+ klog.Infof("[Debug] ramBD: %+v (system=%f)", ramBD, ramBD.System)
|
|
|
+ }
|
|
|
+ for _, result := range resultsRAMUserPct {
|
|
|
+ clusterID, _ := result.GetString("cluster_id")
|
|
|
+ if clusterID == "" {
|
|
|
+ clusterID = defaultClusterID
|
|
|
+ }
|
|
|
+ if _, ok := ramBreakdownMap[clusterID]; !ok {
|
|
|
+ ramBreakdownMap[clusterID] = &ClusterCostsBreakdown{}
|
|
|
+ }
|
|
|
+ ramBD := ramBreakdownMap[clusterID]
|
|
|
+
|
|
|
+ ramBD.User += result.Values[0].Value
|
|
|
+
|
|
|
+ klog.Infof("[Debug] ramBD: %+v (user=%f)", ramBD, ramBD.User)
|
|
|
+ }
|
|
|
+
|
|
|
+ pvUsedCostMap := map[string]float64{}
|
|
|
+ for _, result := range resultsUsedLocalStorage {
|
|
|
+ clusterID, _ := result.GetString("cluster_id")
|
|
|
+ if clusterID == "" {
|
|
|
+ clusterID = defaultClusterID
|
|
|
+ }
|
|
|
+ pvUsedCostMap[clusterID] += result.Values[0].Value
|
|
|
+
|
|
|
+ klog.Infof("[Debug] pvUsedCost[%s]=%f", clusterID, pvUsedCostMap[clusterID])
|
|
|
}
|
|
|
|
|
|
// Convert intermediate structure to Costs instances
|
|
|
@@ -364,18 +393,17 @@ func ComputeClusterCosts(client prometheus.Client, provider cloud.Provider, wind
|
|
|
return nil, err
|
|
|
}
|
|
|
|
|
|
- klog.Infof("[Debug] clusterID: %s", id)
|
|
|
-
|
|
|
if cpuBD, ok := cpuBreakdownMap[id]; ok {
|
|
|
- klog.Infof("[Debug] OK cpuBD: %+v", cpuBD)
|
|
|
-
|
|
|
costs.CPUBreakdown = cpuBD
|
|
|
}
|
|
|
if ramBD, ok := ramBreakdownMap[id]; ok {
|
|
|
- klog.Infof("[Debug] OK ramBD: %+v", ramBD)
|
|
|
-
|
|
|
costs.RAMBreakdown = ramBD
|
|
|
}
|
|
|
+ costs.StorageBreakdown = &ClusterCostsBreakdown{}
|
|
|
+ if pvUC, ok := pvUsedCostMap[id]; ok {
|
|
|
+ costs.StorageBreakdown.Idle = costs.StorageCumulative - pvUC
|
|
|
+ costs.StorageBreakdown.User = pvUC
|
|
|
+ }
|
|
|
|
|
|
costsByCluster[id] = costs
|
|
|
}
|
|
|
@@ -454,7 +482,7 @@ func resultToTotal(qr interface{}) (map[string][][]string, error) {
|
|
|
|
|
|
// ClusterCostsForAllClusters gives the cluster costs averaged over a window of time for all clusters.
|
|
|
func ClusterCostsForAllClusters(cli prometheus.Client, provider cloud.Provider, window, offset string) (map[string]*Totals, error) {
|
|
|
- localStorageQuery := provider.GetLocalStorageQuery(window, offset, true)
|
|
|
+ localStorageQuery := provider.GetLocalStorageQuery(window, offset, true, false)
|
|
|
if localStorageQuery != "" {
|
|
|
localStorageQuery = fmt.Sprintf("+ %s", localStorageQuery)
|
|
|
}
|
|
|
@@ -533,7 +561,7 @@ func AverageClusterTotals(cli prometheus.Client, provider cloud.Provider, window
|
|
|
fmtOffset = fmt.Sprintf("offset %s", offset)
|
|
|
}
|
|
|
|
|
|
- localStorageQuery := provider.GetLocalStorageQuery(windowString, offset, true)
|
|
|
+ localStorageQuery := provider.GetLocalStorageQuery(windowString, offset, true, false)
|
|
|
if localStorageQuery != "" {
|
|
|
localStorageQuery = fmt.Sprintf("+ %s", localStorageQuery)
|
|
|
}
|
|
|
@@ -594,7 +622,7 @@ func AverageClusterTotals(cli prometheus.Client, provider cloud.Provider, window
|
|
|
|
|
|
// ClusterCostsOverTime gives the full cluster costs over time
|
|
|
func ClusterCostsOverTime(cli prometheus.Client, provider cloud.Provider, startString, endString, windowString, offset string) (*Totals, error) {
|
|
|
- localStorageQuery := provider.GetLocalStorageQuery(windowString, offset, true)
|
|
|
+ localStorageQuery := provider.GetLocalStorageQuery(windowString, offset, true, false)
|
|
|
if localStorageQuery != "" {
|
|
|
localStorageQuery = fmt.Sprintf("+ %s", localStorageQuery)
|
|
|
}
|